Biến tần 30kW Altivar ATV340 của Schneider là biến tần 3 pha 400 VAC thuộc họ Altivar
Mã: ATV340D30N4E

– Điện áp: 3 pha 380…480 V – 15…10 %
– Tần số 50…60 Hz +/- 5 %
– 30 kW heavy duty
– Có hỗ trợ truyền thông Ethernet IP, Modbus
– IP20


Biến tần 30kW Altivar ATV340 của Schneider
– Điện áp: 3 pha 380…480 V – 15…10 %
– Tần số 50…60 Hz +/- 5 %
– 30 kW heavy duty
– Có hỗ trợ truyền thông Ethernet IP, Modbus
– IP20
Biến tần 30kW Altivar ATV340 của Schneider là biến tần 3 pha 400 VAC thuộc họ Altivar
Mã: ATV340D30N4E

– Điện áp: 3 pha 380…480 V – 15…10 %
– Tần số 50…60 Hz +/- 5 %
– 30 kW heavy duty
– Có hỗ trợ truyền thông Ethernet IP, Modbus
– IP20


Thông số kỹ thuật – Biến tần 30kW Altivar ATV340 của Schneider
| Range of product | Altivar Machine ATV340 |
|---|---|
| Product or component type | Variable speed drive |
| Product specific application | Machine |
| Mounting mode | Wall mount |
| Variant | Standard version |
| Communication port protocol | EtherNet/IP Modbus TCP Modbus serial |
| Option card | Communication module, PROFINET Communication module, DeviceNet Communication module, CANopen Communication module, EtherCAT |
| Network number of phases | 3 phases |
| Supply frequency | 50…60 Hz +/- 5 % |
| [Us] rated supply voltage | 380…480 V – 15…10 % |
| nominal output current | 61.5 A |
| Motor power kW | 37 kW for normal duty 30 kW for heavy duty |
| Motor power hp | 50 hp for normal duty 40 hp for heavy duty |
| EMC filter | Class C3 EMC filter integrated |
| IP degree of protection | IP20 |
| Degree of protection | UL type 1 |
| Discrete input number | 8 |
|---|---|
| Discrete input type | PTI safe torque off: 0…30 kHz, 24 V DC (30 V) DI1…DI5 programmable as pulse input, 24 V DC (30 V), impedance: 3.5 kOhm programmable |
| number of preset speeds | 16 preset speeds |
| Discrete output number | 1.0 |
| Discrete output type | Programmable output DQ1, DQ2 30 V DC 100 mA |
| Analogue input number | 3 |
| Analogue input type | AI1 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI1 software-configurable temperature probe or water level sensor AI1 software-configurable voltage: 0…10 V DC, impedance: 31.5 kOhm, resolution 12 bits AI2 software-configurable voltage: – 10…10 V DC, impedance: 31.5 kOhm, resolution 12 bits |
| Analogue output number | 2 |
| Analogue output type | Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0…20 mA impedance 500 Ohm, resolution 10 bits |
| Relay output number | 3 |
| Output voltage | <= power supply voltage |
| Relay output type | Relay outputs R1A Relay outputs R1C electrical durability 100000 cycles Relay outputs R2A Relay outputs R2C electrical durability 100000 cycles |
| Maximum switching current | Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Minimum switching current | Relay output R1B: 5 mA at 24 V DC Relay output R2C: 5 mA at 24 V DC |
| Physical interface | 2-wire RS 485 |
| Connector type | 3 RJ45 |
| Method of access | Slave Modbus RTU Slave Modbus TCP |
| Transmission rate | 4.8 kbit/s 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
| Transmission frame | RTU |
| Number of addresses | 1…247 |
| Data format | 8 bits, configurable odd, even or no parity |
| Type of polarization | No impedance |
| 4 quadrant operation possible | True |
| Asynchronous motor control profile | Variable torque standard Optimized torque mode Constant torque standard |
| Synchronous motor control profile | Reluctance motor Permanent magnet motor |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Maximum output frequency | 0.599 kHz |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01…9999 s S, U or customized |
| Motor slip compensation | Automatic whatever the load Not available in permanent magnet motor law Adjustable Can be suppressed |
| Switching frequency | 2…16 kHz adjustable 4…16 kHz with derating factor |
| Nominal switching frequency | 4 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | True |
| Line current | 66.2 A at 380 V (normal duty) 57.3 A at 480 V (normal duty) 54.8 A at 380 V (heavy duty) 48.3 A at 480 V (heavy duty) |
| Line current | 66.2 A at 380 V with internal line choke (normal duty) 57.3 A at 480 V with internal line choke (normal duty) 66.2 A at 380 V with internal line choke (heavy duty) 57.3 A at 480 V with internal line choke (heavy duty) 54.8 A 48.3 A |
| Maximum input current | 66.2 A |
| Maximum output voltage | 480 V |
| Apparent power | 47.6 kVA at 480 V (normal duty) 40.2 kVA at 480 V (heavy duty) |
| Maximum transient current | 89.4 A during 60 s (normal duty) 89.4 A during 2 s (normal duty) 92.3 A during 60 s (heavy duty) 92.3 A during 2 s (heavy duty) |
| Electrical connection | Screw terminal, clamping capacity: 35…50 mm² for line side Screw terminal, clamping capacity: 25…50 mm² for DC bus Screw terminal, clamping capacity: 35…50 mm² for motor Screw terminal, clamping capacity: 0.75…1.5 mm² for control |
| Prospective line Isc | 50 kA |
| Base load current at high overload | 61.5 A |
| Base load current at low overload | 74.5 A |
| Power dissipation in W | Natural convection: 77 W at 380 V, switching frequency 4 kHz (heavy duty) Forced convection: 640 W at 380 V, switching frequency 4 kHz (heavy duty) Natural convection: 90 W at 380 V, switching frequency 4 kHz (normal duty) Forced convection: 796 W at 380 V, switching frequency 4 kHz (normal duty) |
| Electrical connection | Line side: screw terminal 35…50 mm²/AWG 3…AWG 1 DC bus: screw terminal 25…50 mm²/AWG 4…AWG 1 Motor: screw terminal 35…50 mm²/AWG 3…AWG 1 Control: screw terminal 0.75…1.5 mm²/AWG 18…AWG 16 |
| With safety function Safely Limited Speed (SLS) | True |
| With safety function Safe brake management (SBC/SBT) | True |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | True |
| With sft fct Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | True |
| With safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Protection type | Thermal protection: motor Safe torque off: motor Motor phase loss: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive Motor phase loss: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Exceeding limit speed: drive Break on the control circuit: drive |
| Width | 213.0 mm |
| Height | 660.0 mm |
| Depth | 262.0 mm |
| Net weight | 27.9 kg |
| Continuous output current | 74.5 A at 4 kHz for normal duty 61.5 A at 4 kHz for heavy duty |
| Operating altitude | <= 4800 m with current derating above 1000m |
|---|---|
| Operating position | Vertical +/- 10 degree |
| Product certifications | UL CSA TÜV EAC CTick |
| Marking | CE |
| Standards | IEC 61800-3 IEC 61800-5-1 IEC 60721-3 IEC 61508 IEC 13849-1 UL 618000-5-1 UL 508C IEC 61000-3-12 |
| Maximum THDI | <48 % full load conforming to IEC 61000-3-12 <48 % 80 % load conforming to IEC 61000-3-12 |
| Assembly style | With heat sink |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz |
| Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
| Volume of cooling air | 240.0 m3/h |
| Type of cooling | Forced convection |
| Overvoltage category | Class III |
| Regulation loop | Adjustable PID regulator |
| Noise level | 63.5 dB |
| Pollution degree | 2 |
| Ambient air transport temperature | -40…70 °C |
| Ambient air temperature for operation | -15…50 °C without derating (vertical position) 50…60 °C with derating factor (vertical position) |
| Ambient air temperature for storage | -40…70 °C |
| Isolation | Between power and control terminals |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 55.000 cm |
| Package 1 Width | 34.000 cm |
| Package 1 Length | 84.000 cm |
| Package 1 Weight | 35.000 kg |
| Warranty (in months) | 18 |
|---|