Đầu nối Murrelektronik M12 male, M12 female A code có LED, 3 m cáp 7000-40341-6340300 là đầu chuyển đổi giữa M12 4 chân, A-cod, male (đực), 0° với M12 4 chân, A-cod, female (cái), 90°, có sẵn cáp dài 3 m.
(PUR 4×0.34 bk UL/CSA+drag ch. 3m)
3× LED (PNP), (NPN) theo yêu cầu.
Vỏ nhựa có khả năng chống chịu hóa chất và dầu tốt.
Đầu nối Murrelektronik M12 male, M12 female A code có LED, 3 m cáp 7000-40341-6340300
Đầu nối Murrelektronik M12 male, M12 female A code có LED, 3 m cáp 7000-40341-6340300
– Male 0° – female 90°
– M12 – M12, 4-chân, A-cod, có sãn cáp dài 3 m
– IP65, IP66K, IP67
Thông số kỹ thuật – Đầu nối Murrelektronik M12 male, M12 female A code có LED, 3 m cáp 7000-40341-6340300
Cable length | 3 m |
Side 1
Tightening torque | 0,6 Nm |
Mounting method | inserted, screwed |
Family construction form | M12 |
Thread | M12 x 1 |
suitable for corrugated tube (internal Ø) | 10 mm |
Material | PUR |
Width across flats | SW13 |
Degree of protection (EN IEC 60529) | IP65, IP66K, IP67 |
Side 2
Tightening torque | 0,6 Nm |
Mounting method | inserted, screwed |
Family construction form | M12 |
Thread | M12 x 1 |
suitable for corrugated tube (internal Ø) | 10 mm |
Material | PUR |
Width across flats | SW13 |
Degree of protection (EN IEC 60529) | IP65, IP66K, IP67 |
Electrical data | Supply
Operating voltage DC | 24 V |
Operating voltage DC min. | 18 V |
Operating voltage DC max. | 30 V |
Operating voltage DC max. (UL-listed) | 30 V |
Current operating per contact max. | 4 A |
Diagnostics
Status indication LED | green, white, yellow |
Installation | Connection
Mounting set | M12 x 1 |
Device protection | Electrical
Additional condition protection degree | inserted, screwed |
Pollution Degree | 3 |
Rated surge voltage | 0,8 kV |
Material group (IEC 60664-1) | I |
Mechanical data | Material data
Coating locking | Nickeled |
Coating of fitting | nickel plated |
Locking material | Zinc die-casting |
Material screw connection | Zinc die-casting |
Mechanical data | Mounting data
Mounting method | inserted, screwed, Shaking protection |
Environmental characteristics | Climatic
Operating temperature min. | -30 °C |
Operating temperature max. | 85 °C |
Additional condition temperature range | depending on cable quality |
Important installation notes
Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. |
Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. |
Conformity
Product standard | DIN EN 61076-2-101 (M12) |