Đầu nối M12 cái, thẳng, A-code, sẵn cáp 10m của Murrelektronik 7000-40021-6141000
(PVC 4×0.34 bk UL/CSA 10m )
Vỏ nhựa có khả năng chống chịu hóa chất và dầu tốt
Đầu nối M12 cái, thẳng, A-code, sẵn cáp 10m của Murrelektronik 7000-40021-6141000
– Là đầu nối thẳng, có sẵn cáp dài 10m, M12
– Female, 4 chân, A-cod.
– Screwed terminal
– IP65, IP66K, IP67
Đầu nối M12 cái, thẳng, A-code, sẵn cáp 10m của Murrelektronik 7000-40021-6141000
(PVC 4×0.34 bk UL/CSA 10m )
Vỏ nhựa có khả năng chống chịu hóa chất và dầu tốt
Thông số kỹ thuật – Đầu nối M12 cái, thẳng, A-code, sẵn cáp 10m của Murrelektronik 7000-40021-6141000
Cable length | 10 m |
Side 1
Tightening torque | 0,6 Nm |
Mounting method | inserted, screwed |
Family construction form | M12 |
Thread | M12 x 1 |
suitable for corrugated tube (internal Ø) | 10 mm |
Gender | male |
Cable outlet | straight |
Coding | A |
Material | PUR |
No. of poles | 4 |
Width across flats | SW13 |
Degree of protection (EN IEC 60529) | IP65, IP66K, IP67 |
Side 2
Tightening torque | 0,6 Nm |
Mounting method | inserted, screwed |
Family construction form | M12 |
Thread | M12 x 1 |
Gender | female |
suitable for corrugated tube (internal Ø) | 10 mm |
Cable outlet | straight |
Coding | A |
Material | PUR |
No. of poles | 4 |
Width across flats | SW13 |
Degree of protection (EN IEC 60529) | IP65, IP66K, IP67 |
Electrical data | Supply
Operating voltage AC max. | 250 V |
Operating voltage DC max. | 250 V |
Current operating per contact max. | 4 A |
Diagnostics
Status indication LED | no |
Installation | Connection
Mounting set | M12 x 1 |
Device protection | Electrical
Additional condition protection degree | inserted, screwed |
Pollution Degree | 3 |
Rated surge voltage | 2,5 kV |
Material group (IEC 60664-1) | I |
Mechanical data | Material data
Coating locking | Nickeled |
Coating of fitting | nickel plated |
Color contact carrier | green |
Locking material | Zinc die-casting |
Material screw connection | Zinc die-casting |
Mechanical data | Mounting data
Mounting method | inserted, screwed, Shaking protection |
Environmental characteristics | Climatic
Operating temperature min. | -30 °C |
Operating temperature max. | 85 °C |
Additional condition temperature range | depending on cable quality |
Important installation notes
Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. |
Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. |
Conformity
Product standard | DIN EN 61076-2-101 (M12) |