Đầu nối M12 có cáp Murrelektronik 7000-12341-6141500
(PVC 4×0.34 bk UL/CSA 15m )

Vỏ nhựa có khả năng chống chịu hóa chất và dầu tốt
Đầu nối M12 có cáp Murrelektronik 7000-12341-6141500
– Là đầu nối 90°, có sẵn cáp dài 15m, M12
– Female, 4 chân, A-cod.
– Screwed terminal
– IP65, IP66K, IP67
Đầu nối M12 có cáp Murrelektronik 7000-12341-6141500
(PVC 4×0.34 bk UL/CSA 15m )

Vỏ nhựa có khả năng chống chịu hóa chất và dầu tốt
Thông số kỹ thuật – Đầu nối M12 có cáp Murrelektronik 7000-12341-6141500
| Cable length | 15 m | 
Side 1
| Tightening torque | 0,6 Nm | 
| Mounting method | inserted, screwed | 
| Coating contact | gold plated | 
| Family construction form | M12 | 
| Thread | M12 x 1 | 
| suitable for corrugated tube (internal Ø) | 10 mm | 
| Cable outlet | angled | 
| Coding | A | 
| Material contact | Copper alloy | 
| Material | PUR | 
| No. of poles | 4 | 
| Width across flats | SW13 | 
| Degree of protection (EN IEC 60529) | IP65, IP66K, IP67 | 
Side 2
| Stripping length (jacket) | 20 mm | 
| Family construction form | free cable end | 
Electrical data | Supply
| Operating voltage AC max. | 250 V | 
| Operating voltage DC max. | 250 V | 
| Current operating per contact max. | 4 A | 
Diagnostics
| Status indication LED | no | 
Installation | Connection
| Stripping length (jacket) | 20 mm | 
| Mounting set | M12 x 1 | 
| Gender | female | 
Device protection | Electrical
| Degree of protection (EN IEC 60529) | IP65, IP67, IP66K | 
| Additional condition protection degree | inserted, screwed | 
| Pollution Degree | 3 | 
| Rated surge voltage | 2,5 kV | 
| Material group (IEC 60664-1) | I | 
Mechanical data | Material data
| Coating locking | Nickeled | 
| Coating of fitting | nickel plated | 
| Material gasket | FKM | 
| Locking material | Zinc die-casting | 
| Material screw connection | Zinc die-casting | 
Mechanical data | Mounting data
| Mounting method | inserted, screwed, Shaking protection | 
Environmental characteristics | Climatic
| Operating temperature min. | -30 °C | 
| Operating temperature max. | 85 °C | 
| Additional condition temperature range | depending on cable quality | 
Important installation notes
| Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. | 
| Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. | 
Conformity
| Product standard | DIN EN 61076-2-101 (M12) |